{"id":29465,"date":"2015-09-17T12:56:13","date_gmt":"2015-09-17T10:56:13","guid":{"rendered":"https:\/\/www.esseci.com\/?p=473"},"modified":"2015-09-17T12:56:13","modified_gmt":"2015-09-17T10:56:13","slug":"serie-i2net-3","status":"publish","type":"post","link":"https:\/\/webstaging.esseci.com\/?p=29465","title":{"rendered":"I2Net Series"},"content":{"rendered":"<p>The <strong><em>i<\/em><\/strong><strong><em><sup>2<\/sup><\/em><\/strong><strong><em>Net Series<\/em><\/strong> includes serial master terminals and slave modules specifically developed for the central control of large plants made of up to 30 areas, heated by standard or aerated, single or multi-stage gas-fired burners. The serial master terminal is also available with setup and monitoring by PC and software EYE-LAN and ModBus protocol.<\/p>\n<p>Available versions:<\/p>\n<ul>\n<li>With software EYELAN developed by EsseCI to monitor the network by PC;<\/li>\n<li>With open structure and ModBus RTU port for the connection to existing monitoring systems, ModBus compatible;<\/li>\n<li>BACnet port, for the connection to HVAC network (contact EsseCI for further info);<\/li>\n<li><span style=\"line-height: 1.42857;\">Bidirectional router to extend the network up to 60 heaters;<\/span><\/li>\n<\/ul>\n<h3><strong>SERIAL MASTER TERMINAL\u00a0<\/strong><\/h3>\n<ul>\n<li>\n<h4><strong>SCM850B<\/strong><\/h4>\n<\/li>\n<\/ul>\n<p><strong>Serial master terminal equipped with a <\/strong><strong>large backlit LCD display<\/strong>: it ensures easy viewing and provides clear information at a glance about alarm and events in progress. Every parameter is accompanied by a scrolling text message which describes its function and makes device and network even easier and quicker to setup. <strong>A PC is not required<\/strong> to use and set up network and device itself. The SCM850 controls <strong>up to 60 zone modules (60 heating zones)<\/strong> independently; each of them has its proper room probe (or network probe) and daily \/ weekly setting. The SCM850 features 2 room probe inputs, to which it is possible to enslave the functioning of the serial slave unit. Doing so, you create <strong>2 macro heating areas<\/strong>: it is <strong>the ideal solution to manage large plants heated by warm air generators.<\/strong> To connect the master device SCM850 to your PC and use the setup and monitoring software<strong> EYE-LAN, the TCP-IP expansion slot is required<\/strong> (this option may be purchased at any time).<\/p>\n<ul>\n<li>\n<h4><strong>SCM805D<\/strong><\/h4>\n<\/li>\n<\/ul>\n<p><strong>Serial master terminal equipped with LED display + icons. <\/strong>It controls up to <strong>60 zone modules independently<\/strong>, that is 60 heating zones; each of them has its proper room probe (or network probe) and daily \/ weekly setting. <strong>To setup and monitor the entire network<\/strong> (SCM805 + serial slave units + sensors connected)<strong> a PC with the software EYELAN installed is required<\/strong>. The SCM805 is supplied with the software pack EYE-LAN LITE.<\/p>\n<h3><strong>SERIAL SLAVE MODULES<\/strong><\/h3>\n<h4><strong>Zone chrono-thermostat for single-flame burner<\/strong><\/h4>\n<ul>\n<li><strong>SCQ60: <\/strong>Chrono-thermostat to control 1 heating zone with<strong> 4 single flame heaters<\/strong>: 8 outputs (TA1-2-3-4, RT1-2-3-4) and 8 inputs AC (ON1-2-3-4, BLOCK\u00a01-2-3-4).\n<ul>\n<li>Display of temperature, time and days;<\/li>\n<li><strong>8 <\/strong><strong>device indicator lights<\/strong>: 4 ON\/ 4 alarm;<\/li>\n<li><strong>RESET <\/strong>of all devices or of the lockout devices by key;<\/li>\n<li>Possibility to <strong>exclude 1 or more devices<\/strong> by key;<\/li>\n<li><strong>IFS tools <\/strong>to program and update the device by PC;<\/li>\n<li><span style=\"line-height: 1.42857;\"><strong>Black bulb probe with key selector<\/strong>.<\/span><\/li>\n<\/ul>\n<\/li>\n<li><strong><strong>SCQ71: \u00a0<\/strong><\/strong>Chrono-thermostat to control 1 heating zone with <strong>2 single flame heaters<\/strong>: 3 outputs (TA1, TA2, RT) and 4 AC inputs AC (ON1-2, BLOCK1-2).\n<ul>\n<li>Housing: main electronic board<strong> without display<\/strong> panel;<\/li>\n<li><strong>4\u00a0<\/strong><strong>device indicator lights<\/strong>: 2\u00a0ON\/ 2 alarm;<\/li>\n<li><strong>RESET <\/strong>of all devices or of the lockout devices by key;<\/li>\n<li>Possibility to <strong>exclude 1 or more devices<\/strong> by key;<\/li>\n<li><strong>IFS tools <\/strong>to program and update the device by PC;<\/li>\n<li><span style=\"line-height: 1.42857;\"><strong>Black bulb probe with key selector<\/strong>.<\/span><\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<h4><strong>Zone chrono-thermostat for two-flame burner<\/strong><\/h4>\n<ul>\n<li><strong>SCQ72: <\/strong>Chrono-thermostat to control 1 heating zone with <strong>1 two-flame burner<\/strong>: 3 outputs (TA-LO, TA-HI, RT) and 6 AC inputs (ON_LO, ON-HI, BLOCK, AUX1-2-3).\n<ul>\n<li><strong>4 <\/strong><strong>device indicator lights<\/strong> for device status;<\/li>\n<li><strong>Wide reset<\/strong>, max power at heating plant start up, etc.;<\/li>\n<li><strong>Built-in timer<\/strong>: to set the working periods of every single heater;<\/li>\n<li><strong>IFS tools <\/strong>to program and update the device by PC;<\/li>\n<li><strong>Black bulb probe with key selector<\/strong>.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<h4><strong>Zone chrono-thermostat for more single-flame burners <\/strong><\/h4>\n<ul>\n<li><strong>SCQ65: <\/strong><em>i<sup>2<\/sup>Net <\/em>control unit for <em>iNet<\/em> sub-network<em>:<\/em> 1 heating zone made of serial subnet of up 16 modules SCHH10 corresponding to 16 single stage heaters. The device makes it possible to manage an <strong><em>iNet <\/em><\/strong>network by an <strong><em>i<sup>2<\/sup>Net <\/em><\/strong>terminal and by EYELAN software<em>.<\/em><\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h3><strong>SERIAL \/ STAND ALONE CONTROL UNIT<\/strong><\/h3>\n<p><strong>SCB40<\/strong>: New chrono-thermostat, highly configurable, which allows distributors and OEMs greater stock optimization and storage capacity: just one device suitable to 10 different applications. Indeed it may be used as stand-alone or network solution supervised by PC thanks to the EYE-LAN software. It features 6 outputs (4 burners + 1 RESET + 1 FAN) and it can be set by parameter in 9 different working modes to control: 1 or 2 heating zones, up to 4 single flame burners \/ warm air generators or 2 independent two-flame burners with or without common exhaust fan.<\/p>\n<h4><strong>TECHNICAL FEATURES:<\/strong><\/h4>\n<ul>\n<li>1 AC input for burner lockout indicator light;<\/li>\n<li>5 probe inputs: 2 BMS inputs (remote on\/off), 2 room probe inputs, 1 external probe input;<\/li>\n<li>6 outputs: 4 burner outputs (TA1-4 or TA_Hi1-2 and TA_Lo1-2), 1 RST output and FAN output;<\/li>\n<li>Serial port for SCBus protocol and possibility to be monitored by the EYE-LAN software;<\/li>\n<li>Wide reset, max power at heating plant start up, etc.;<\/li>\n<li>Built-in timer.<\/li>\n<li>IFS tools to program and update the device by PC.<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h4><strong>EXAMPLES OF APPLICATION:<\/strong><\/h4>\n<ol>\n<li>1 Heating Zone with 4 single-stage independent burners.<\/li>\n<li>1 Heating Zone with 4 single-stage independent burners e ventola collettiva per aspirazione fumi.<\/li>\n<li>2 Heating Zones with 2 single-stage independent burners each.<\/li>\n<li>2 Heating Zones with 2 single-stage independent burners each and common exhaust fan.<\/li>\n<li>1 Heating Zone with 2 two-stage independent burners.<\/li>\n<li>1 Heating Zone with 2 two-stage independent burners and common exhaust fan.<\/li>\n<li>2 Heating Zones with 1 two-stage independent burner each.<\/li>\n<li>2 Heating Zones with 1 two-stage independent burners each and common exhaust.<\/li>\n<li>1 Heating Zone with 4 independent warm air generators.<\/li>\n<li>2 Heating Zones: Zone 1 =\u00a02 single-stage independent burners and\u00a0common exhaust fan \u00a0\/\/ \u00a0Zone 2 =\u00a02 single-stage independent burners<\/li>\n<\/ol>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>The i2Net Series includes serial master terminals and slave modules specifically developed for the central control of large plants made<\/p>\n","protected":false},"author":1,"featured_media":29405,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[203,198,205],"tags":[],"class_list":["post-29465","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-hvac-en","category-prodotti-en","category-riscaldamento-radiante-en"],"acf":[],"_links":{"self":[{"href":"https:\/\/webstaging.esseci.com\/index.php?rest_route=\/wp\/v2\/posts\/29465","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/webstaging.esseci.com\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/webstaging.esseci.com\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/webstaging.esseci.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/webstaging.esseci.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=29465"}],"version-history":[{"count":0,"href":"https:\/\/webstaging.esseci.com\/index.php?rest_route=\/wp\/v2\/posts\/29465\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/webstaging.esseci.com\/index.php?rest_route=\/wp\/v2\/media\/29405"}],"wp:attachment":[{"href":"https:\/\/webstaging.esseci.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=29465"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/webstaging.esseci.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=29465"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/webstaging.esseci.com\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=29465"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}