{"id":470,"date":"2015-09-17T10:17:15","date_gmt":"2015-09-17T08:17:15","guid":{"rendered":"https:\/\/www.esseci.com\/?p=470"},"modified":"2015-09-17T10:17:15","modified_gmt":"2015-09-17T08:17:15","slug":"serie-inet-2","status":"publish","type":"post","link":"https:\/\/webstaging.esseci.com\/?p=470","title":{"rendered":"INet Series"},"content":{"rendered":"<p>Chrono-thermostats for the control of up to 4 heating areas, each of them with room probe and daily \/ weekly setting. The system is made of a serial master terminal, which controls one or more serial slave modules.<\/p>\n<h3><strong>SERIAL MASTER TERMINAL: <\/strong><\/h3>\n<p><strong>The serial master terminal <\/strong>features <strong>a large LED display,<\/strong> which ensures an easy viewing. Device and whole network setup is quick and intuitive.<\/p>\n<p>To setup and monitor the entire network by PC and software <strong>EYELAN<\/strong>, you just need to replace the serial master terminal SCH13x with the control unit SCQ65 and connect it to the serial mater terminal SCM850.<\/p>\n<p><strong>Housing<\/strong>: panel or wall mounted.<\/p>\n<p><strong>Application<\/strong>: standard \/ aerated, single\/multi-stage gas fired burners.<\/p>\n<p><strong>Versions:<\/strong><\/p>\n<ul>\n<li><strong>SCH130A<\/strong>: 1 heating zone, 16 power modules;<\/li>\n<li><strong>SCH131A<\/strong>: 2 heating zones, 16 power modules;<\/li>\n<li><strong>SCH132A<\/strong>: 3 heating zones, 16 power modules;<\/li>\n<li><strong>SCH133A<\/strong>: 4 heating zones, 16 power modules;<\/li>\n<li><strong>SCH134A<\/strong>: 1 heating zone, 1 two-flame power module (SCHH50)<\/li>\n<li><strong>SCQ65<\/strong>: <em>i<sup>2<\/sup>Net <\/em>control unit for <em>iNet<\/em> sub-network<em>:<\/em> 1 heating zone made of serial subnet of up 16 modules SCHH10 corresponding to 16 single stage heaters. The device makes it possible to manage an <strong><em>iNet <\/em><\/strong>network by an <strong><em>i<sup>2<\/sup>Net <\/em><\/strong>terminal and by EYELAN software<em>. <\/em><\/li>\n<\/ul>\n<h3><strong>SERIAL SLAVE MODULES:<\/strong><\/h3>\n<p>Many different versions of power modules have been developed in order to increase the number of possible applications and fulfill the needs of every heating plant:<\/p>\n<ul>\n<li><strong>SCHH10<\/strong>: for single stage radiant panels, 2 outputs (TA, RT) 2 AC inputs (ON, BLOCK);<\/li>\n<li><strong>SCHH20<\/strong>: for single stage warm air generators, 3 outputs (TA, RT, FAN) 2 AC inputs (ON, BLOCK).<\/li>\n<li><strong>SCHH30<\/strong>: for two-stage radiant panels \/ warm air generators, 4 outputs (TA-LO, TA-HI, RT, FAN) 3 inputs AC (ON-LO, ON-HI, BLOCK);<\/li>\n<li><strong>SCHH40<\/strong>: for warm air generators \/ radiant lamps with blown gas burner (to be combined only with SCH13X option PWM burners): 1 output (TA + PWM fan burner command) 2 AC inputs (ON, BLOCK)<\/li>\n<li><strong>SCHH50<\/strong>: for high efficiency two-stage radiant stripes (to be combined only with SCH134): 3 outputs (TA-LO, TA-HI, RT) 4 AC inputs (ON-LO, ON-HI, BLOCK, ALARM)<\/li>\n<\/ul>\n<p><em><strong>\u201cClone\u201d function:<\/strong> <\/em>to clone one or more remote units. This function is particularly useful in those cases where the enlargement of an existing plant is required: it enables indeed to exceed the number of 16 units permitted up to max 24 units, 8 of which are \u201cclones\u201d.<\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Chrono-thermostats for the control of up to 4 heating areas, each of them with room probe and daily \/ weekly<\/p>\n","protected":false},"author":1,"featured_media":231,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[203,198,205],"tags":[],"class_list":["post-470","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-hvac-en","category-prodotti-en","category-riscaldamento-radiante-en"],"acf":[],"_links":{"self":[{"href":"https:\/\/webstaging.esseci.com\/index.php?rest_route=\/wp\/v2\/posts\/470","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/webstaging.esseci.com\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/webstaging.esseci.com\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/webstaging.esseci.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/webstaging.esseci.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=470"}],"version-history":[{"count":0,"href":"https:\/\/webstaging.esseci.com\/index.php?rest_route=\/wp\/v2\/posts\/470\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/webstaging.esseci.com\/index.php?rest_route=\/wp\/v2\/media\/231"}],"wp:attachment":[{"href":"https:\/\/webstaging.esseci.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=470"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/webstaging.esseci.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=470"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/webstaging.esseci.com\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=470"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}