{"id":601,"date":"2015-09-25T15:21:21","date_gmt":"2015-09-25T13:21:21","guid":{"rendered":"https:\/\/www.esseci.com\/?p=601"},"modified":"2015-09-25T15:21:21","modified_gmt":"2015-09-25T13:21:21","slug":"unita-trattamento-aria-2","status":"publish","type":"post","link":"https:\/\/webstaging.esseci.com\/?p=601","title":{"rendered":"AIR TREATMENT UNITS CONTROL"},"content":{"rendered":"<p>The series includes serial master terminals and slave modules specifically developed for the central control of large plants made of up to 30 areas, heated by total condensing single-package Air Treatment Units.<\/p>\n<p>Available versions:<\/p>\n<ul>\n<li>With software EYELAN developed by EsseCI to monitor the network by PC;<\/li>\n<li>With open structure and ModBus RTU port for the connection to existing monitoring systems, ModBus compatible;<\/li>\n<li>BACnet port, for the connection to HVAC network (contact EsseCI for further info);<\/li>\n<li>Bidirectional router to extend the network up to 60 heaters;<\/li>\n<\/ul>\n<h3><strong>SERIAL MASTER TERMINAL\u00a0<\/strong><\/h3>\n<ul>\n<li><strong>SCM850B<\/strong><\/li>\n<\/ul>\n<p><strong>Serial master terminal equipped with a\u00a0large backlit LCD display<\/strong>: it ensures easy viewing and provides clear information at a glance about alarm and events in progress. Every parameter is accompanied by a scrolling text message which describes its function and makes device and network even easier and quicker to setup.\u00a0<strong>A PC is not required<\/strong>\u00a0to use and set up network and device itself. The SCM850 controls\u00a0<strong>up to 60 zone modules (60 heating zones)<\/strong>\u00a0independently; each of them has its proper room probe (or network probe) and daily \/ weekly setting. The SCM850 features 2 room probe inputs, to which it is possible to enslave the functioning of the serial slave unit. Doing so, you create\u00a0<strong>2 macro heating areas<\/strong>: it is\u00a0<strong>the ideal solution to manage large plants heated by warm air generators.<\/strong>\u00a0To connect the master device SCM850 to your PC and use the setup and monitoring software<strong>\u00a0EYE-LAN, the TCP-IP expansion slot is required<\/strong>\u00a0(this option may be purchased at any time).<\/p>\n<ul>\n<li><strong>SCM805D<\/strong><\/li>\n<\/ul>\n<p><strong>Serial master terminal equipped with LED display + icons.\u00a0<\/strong>It controls up to\u00a0<strong>60 zone modules independently<\/strong>, that is 60 heating zones; each of them has its proper room probe (or network probe) and daily \/ weekly setting.\u00a0<strong>To setup and monitor the entire network<\/strong>\u00a0(SCM805 + serial slave units + sensors connected)<strong>\u00a0a PC with the software EYELAN installed is required<\/strong>. The SCM805 is supplied with the software pack EYE-LAN LITE.<\/p>\n<p>&nbsp;<\/p>\n<h3><strong>SERIAL SLAVE MODULES<\/strong><\/h3>\n<ul>\n<li><strong>SCQ80:<\/strong> New electronic controller specifically designed for total condensing single-package Air Treatment Units.\n<ul>\n<li>Control of <strong>temperature<\/strong> and <strong>speed<\/strong> of the <strong>outlet air flow<\/strong>;<\/li>\n<li>Control of air renovation by\u00a0 regulating the outside air damper;<\/li>\n<li>Control of 1 modulating and\/or variable thermal power burner;<\/li>\n<li>Connection to a monitoring network;<\/li>\n<li>Command of cooling unit for the winter-summer air treatment;<\/li>\n<li><strong>Built-in timer<\/strong>: optimization of working periods according to the thermal efficiency of every single heater;<\/li>\n<li><strong>IFS tools\u00a0<\/strong>to program and update the device by PC.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>The series includes serial master terminals and slave modules specifically developed for the central control of large plants made of<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[203,198],"tags":[],"class_list":["post-601","post","type-post","status-publish","format-standard","hentry","category-hvac-en","category-prodotti-en"],"acf":[],"_links":{"self":[{"href":"https:\/\/webstaging.esseci.com\/index.php?rest_route=\/wp\/v2\/posts\/601","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/webstaging.esseci.com\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/webstaging.esseci.com\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/webstaging.esseci.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/webstaging.esseci.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=601"}],"version-history":[{"count":0,"href":"https:\/\/webstaging.esseci.com\/index.php?rest_route=\/wp\/v2\/posts\/601\/revisions"}],"wp:attachment":[{"href":"https:\/\/webstaging.esseci.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=601"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/webstaging.esseci.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=601"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/webstaging.esseci.com\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=601"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}